Table: GENUNITS

GENUNITS

Name

GENUNITS

Comment

GENUNITS shows Genset details for each physical unit with the relevant station.


Description

GENUNITS is a public table, and is available to all participants.

Source

GENUNITS updates whenever plant details change.


Primary Key Columns

Name

GENSETID


Index Columns

Name

LASTCHANGED


Content

Name

Data Type

Mandatory

Comment

GENSETID

VARCHAR2(20)

X

Physical Unit identifier

STATIONID

VARCHAR2(10)

 

Station Identifier

SETLOSSFACTOR

NUMBER(16,6)

 

Not used

CDINDICATOR

VARCHAR2(10)

 

Centrally dispatched Indicator

AGCFLAG

VARCHAR2(2)

 

AGC Available flag

SPINNINGFLAG

VARCHAR2(2)

 

Not used

VOLTLEVEL

NUMBER(6,0)

 

Voltage level

REGISTEREDCAPACITY

NUMBER(6,0)

 

Registered capacity

DISPATCHTYPE

VARCHAR2(20)

 

Identifies LOAD, GENERATOR or BIDIRECTIONAL. This will likely expand to more generic models as new technology types are integrated into the NEM.

STARTTYPE

VARCHAR2(20)

 

Fast / Slow / Not Dispatched

MKTGENERATORIND

VARCHAR2(10)

 

Market Generator Indicator Flag

NORMALSTATUS

VARCHAR2(10)

 

On / Off for load

MAXCAPACITY

NUMBER(6,0)

 

Maximum capacity

GENSETTYPE

VARCHAR2(15)

 

Genset type

GENSETNAME

VARCHAR2(40)

 

Genset name

LASTCHANGED

DATE

 

Last date and time record changed

CO2E_EMISSIONS_FACTOR

NUMBER(18,8)

 

The emissions factor for the generating unit, as calculated by Settlements staff members

CO2E_ENERGY_SOURCE

VARCHAR2(100)

 

The energy source for the generating unit, as used in the calculation of the CO2-e emissions factor. Distinct from the Energy Source for a generating unit published as part of the Registration Master List

CO2E_DATA_SOURCE

VARCHAR2(20)

 

An indicator as to the source of the emission factor used in the calculation of the index. The applicable values for this field would be NTNDP which indicates the emission factor is quoted from the National Transmission Network Development Plan or Estimated to indicate the emission factor has been calculated using an internal AEMO procedure based upon the Department of Climate Change and Energy Efficiency NGA factors

MINCAPACITY

NUMBER(6,0)

 

Minimum capacity only for load side of BDU, otherwise 0 (MW)

REGISTEREDMINCAPACITY

NUMBER(6,0)

 

Registered minimum capacity only for load side of BDU, otherwise 0 (MW)

MAXSTORAGECAPACITY

NUMBER(15,5)

 

The rated storage capacity (MWh), information only