Name |
|
Comment |
Price Sensitivies for 5MinPD solution. New solution every 5 minutes. Current Scenarios defined in P5MIN_SCENARIODEMANDTRK/P5MIN_SCENARIODEMAND |
Name |
INTERCONNECTORID |
INTERVAL_DATETIME |
RUN_DATETIME |
Name |
Data Type |
Mandatory |
Comment |
RUN_DATETIME |
DATE |
X |
Definitive Run from which this solution derives |
INTERCONNECTORID |
VARCHAR2(20) |
X |
Interconnector identifier |
INTERVAL_DATETIME |
DATE |
X |
The unique identifier for the interval within this study |
INTERVENTION |
NUMBER(1,0) |
X |
Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0) |
INTERVENTION_ACTIVE |
NUMBER(1,0) |
|
Flag to indicate if the sensitivity run contains an active intervention constraint: 0 = No, 1 = Yes |
MWFLOW1 |
NUMBER(15,5) |
|
MW Flow value. Flow1 = MW flow for given Interconnector for Scenario 1 |
MWFLOW2 |
NUMBER(15,5) |
|
MW Flow value. Flow2 = MW flow for given Interconnector for Scenario 2 |
MWFLOW3 |
NUMBER(15,5) |
|
MW Flow value. Flow3 = MW flow for given Interconnector for Scenario 3 |
MWFLOW4 |
NUMBER(15,5) |
|
MW Flow value. Flow4 = MW flow for given Interconnector for Scenario 4 |
MWFLOW5 |
NUMBER(15,5) |
|
MW Flow value. Flow5 = MW flow for given Interconnector for Scenario 5 |
MWFLOW6 |
NUMBER(15,5) |
|
MW Flow value. Flow6 = MW flow for given Interconnector for Scenario 6 |
MWFLOW7 |
NUMBER(15,5) |
|
MW Flow value. Flow7 = MW flow for given Interconnector for Scenario 7 |
MWFLOW8 |
NUMBER(15,5) |
|
MW Flow value. Flow8 = MW flow for given Interconnector for Scenario 8 |
MWFLOW9 |
NUMBER(15,5) |
|
MW Flow value. Flow9 = MW flow for given Interconnector for Scenario 9 |
MWFLOW10 |
NUMBER(15,5) |
|
MW Flow value. Flow10 = MW flow for given Interconnector for Scenario 10 |
MWFLOW11 |
NUMBER(15,5) |
|
MW Flow value. Flow11 = MW flow for given Interconnector for Scenario 11 |
MWFLOW12 |
NUMBER(15,5) |
|
MW Flow value. Flow12 = MW flow for given Interconnector for Scenario 12 |
MWFLOW13 |
NUMBER(15,5) |
|
MW Flow value. Flow13 = MW flow for given Interconnector for Scenario 13 |
MWFLOW14 |
NUMBER(15,5) |
|
MW Flow value. Flow14 = MW flow for given Interconnector for Scenario 14 |
MWFLOW15 |
NUMBER(15,5) |
|
MW Flow value. Flow15 = MW flow for given Interconnector for Scenario 15 |
MWFLOW16 |
NUMBER(15,5) |
|
MW Flow value. Flow16 = MW flow for given Interconnector for Scenario 16 |
MWFLOW17 |
NUMBER(15,5) |
|
MW Flow value. Flow17 = MW flow for given Interconnector for Scenario 17 |
MWFLOW18 |
NUMBER(15,5) |
|
MW Flow value. Flow18 = MW flow for given Interconnector for Scenario 18 |
MWFLOW19 |
NUMBER(15,5) |
|
MW Flow value. Flow19 = MW flow for given Interconnector for Scenario 19 |
MWFLOW20 |
NUMBER(15,5) |
|
MW Flow value. Flow20 = MW flow for given Interconnector for Scenario 20 |
MWFLOW21 |
NUMBER(15,5) |
|
MW Flow value. Flow21 = MW flow for given Interconnector for Scenario 21 |
MWFLOW22 |
NUMBER(15,5) |
|
MW Flow value. Flow22 = MW flow for given Interconnector for Scenario 22 |
MWFLOW23 |
NUMBER(15,5) |
|
MW Flow value. Flow23 = MW flow for given Interconnector for Scenario 23 |
MWFLOW24 |
NUMBER(15,5) |
|
MW Flow value. Flow24 = MW flow for given Interconnector for Scenario 24 |
MWFLOW25 |
NUMBER(15,5) |
|
MW Flow value. Flow25 = MW flow for given Interconnector for Scenario 25 |
MWFLOW26 |
NUMBER(15,5) |
|
MW Flow value. Flow26 = MW flow for given Interconnector for Scenario 26 |
MWFLOW27 |
NUMBER(15,5) |
|
MW Flow value. Flow27 = MW flow for given Interconnector for Scenario 27 |
MWFLOW28 |
NUMBER(15,5) |
|
MW Flow value. Flow28 = MW flow for given Interconnector for Scenario 28 |
MWFLOW29 |
NUMBER(15,5) |
|
MW Flow value. Flow29 = MW flow for given Interconnector for Scenario 29 |
MWFLOW30 |
NUMBER(15,5) |
|
MW Flow value. Flow30 = MW flow for given Interconnector for Scenario 30 |
MWFLOW31 |
NUMBER(15,5) |
|
MW Flow value. Flow31 = MW flow for given Interconnector for Scenario 31 |
MWFLOW32 |
NUMBER(15,5) |
|
MW Flow value. Flow32 = MW flow for given Interconnector for Scenario 32 |
MWFLOW33 |
NUMBER(15,5) |
|
MW Flow value. Flow33 = MW flow for given Interconnector for Scenario 33 |
MWFLOW34 |
NUMBER(15,5) |
|
MW Flow value. Flow34 = MW flow for given Interconnector for Scenario 34 |
MWFLOW35 |
NUMBER(15,5) |
|
MW Flow value. Flow35 = MW flow for given Interconnector for Scenario 35 |
MWFLOW36 |
NUMBER(15,5) |
|
MW Flow value. Flow36 = MW flow for given Interconnector for Scenario 36 |
MWFLOW37 |
NUMBER(15,5) |
|
MW Flow value. Flow37 = MW flow for given Interconnector for Scenario 37 |
MWFLOW38 |
NUMBER(15,5) |
|
MW Flow value. Flow38 = MW flow for given Interconnector for Scenario 38 |
MWFLOW39 |
NUMBER(15,5) |
|
MW Flow value. Flow39 = MW flow for given Interconnector for Scenario 39 |
MWFLOW40 |
NUMBER(15,5) |
|
MW Flow value. Flow40 = MW flow for given Interconnector for Scenario 40 |
MWFLOW41 |
NUMBER(15,5) |
|
MW Flow value. Flow41 = MW flow for given Interconnector for Scenario 41 |
MWFLOW42 |
NUMBER(15,5) |
|
MW Flow value. Flow42 = MW flow for given Interconnector for Scenario 42 |
MWFLOW43 |
NUMBER(15,5) |
|
MW Flow value. Flow43 = MW flow for given Interconnector for Scenario 43 |
LASTCHANGED |
DATE |
|
Timestamp when this record was last modified |
|
|
|